Hello Everyone,
I'm trying to model an extended shear tab connection using ABAQUS 6.13-2, I've tried to model 4 connections and I compared the results I've got with the experimental work, and I noticed that the FEA is way stiffer that the experimental work, I have only one warning and it says "If significant clearance/overclosure exists between surface pair (assembly__pickedsurf579,assembly__pickedsurf580) and the master surface does not have rotational degrees of freedom, adjustment is recommended for correct enforcement of the tie constraint"