Abaqus equivalent of MSC.Marc's element #144
Hi All,
Any idea what would be Abaqus equivalent of Marc's rebar element #144? Thanks in advance.
Regards, Mike
Hi All,
Any idea what would be Abaqus equivalent of Marc's rebar element #144? Thanks in advance.
Regards, Mike
The Quasi-static method for dynamic problem in Abaqus should be carefully used, because it will automatically induce the numerical damping in your calculation.
This method is very conservative, approximately it will introduce 5% numerical damping (damping ratio).
This method is helpful for contact problem and for convergency. But be careful when using it.
Normal
0
false
false
false
EN-US
ZH-CN
X-NONE
Hi all,
my question is about the history data storage in FEAP.
I am writing element subroutine (elmt01) in FEAP 8.3 for a history dependent problem.
I have written the stiffness matrix subroutine (stiff01), but it needs the data from the previous solution steps (previous strains, stresses, plastic strains, dislocation densities .... nh1,nh2=30 per point).
School of Engineering
LRET Lecturer/Senior Lecturer/Reader in Safety and Reliability Engineering
Reference Number 1231244
Building on a 20-year track record in safety engineering, the School of Engineering at the University of Aberdeen in partnership with The Lloyd's Register Educational Trust (The LRET) is establishing a centre of excellence for research and teaching in the safety and reliability of engineering systems, structures and processes.
hai
can we do laser machining of composites materials like glass fiber etc.. from simple laser machine or we have to use special fiber laser for this..please through some light on this topic....
Traditional ways of valve inspection using a contact profilometer are making way for the more recent non contact valve inspection technologies. Even though many of the specs of surface roughness globally are set as per the findings by a contact profilometer the ease of non-contact inspection systems plus the speedier technique of employing the high tech valve inspection technologies are definitely behind why significantly more professionals are purchasing the newest non-contact profilometer.
Great things about a customized valve inspection set-up
Editors-in-Chief (July 2011-June 2015)
Dear Colleagues, On behalf of the CM13 Organising Committee, I would like to invite you to attend an International Conference on Computational Mechanics - CM13, to be held in Durham, UK from 25-27 March 2013. The conference is organised under the banner of the UK Association of Computational Mechanics in Engineering (ACME) replacing, for 2013, the annual ACME meeting with a much larger and truly international event. A flyer containing full details of the conference can be downloaded here.
Hi all. I am running forming analysis on abaqus 6.10 on 64 bit platform with 8 gb of RAM. How can I give max memory usage for abaqus/explicit? There is a built in option for abaqus/implicit but for explicit there is no such option.
I want to allocate max amount of RAM for the analysis. Please help me with that.