My thermal simulation in the alternator required convective coefficient . Presently i have computed convective coefficient for stator,rotor,rectifier assembly by thermal testing at steady state condition. I have completed thermal simulation for these components of the alternator . Next, i want to perform thermal simulation for entire alternator.Is there anybody, provide me guidance to formulate correlation between geomentry,ambient condition,convective flim coefficient.Further, i have to model contact among components in the alternator. it requires thermal contact conductance.