ABAQUS CAE can not find the time step

Dear All,

Because i am absolutely new in ABAQUS CAE, i have some problem.

I have created my first model with ABAQUS CAE and the problem which i force,- i don't see the option where i should put the time , So my simulations have only one point. Have anybody has the same problem.

You kind help will be highly appreciated.

 

ABAgirl

Comments

I need your help

You put the time in the step definition, typically. However, if you are using a linear perturbation step you don't specify the time. If you want to specify the time try a general step instead.

 

My Company - Red Cedar Technology

Hello Marcus,

yes i put explicitly the time definition and nevertheless there is only one simple step.** STEP: Step-1
**
*Step, name=Step-1, perturbation, AMPLITUDE=RAMP, INC=200
10 kN central load
*Static
0., 1, 0.0001, 0.01
**
** LOADS
**
** Name: Force   Type: Concentrated force
*Cload
_PickedSet6, 2, -10000.
**
** OUTPUT REQUESTS
**
**
** FIELD OUTPUT: F-Output-1
**
*Output, field, variable=PRESELECT, Frequency=1
**
** HISTORY OUTPUT: H-Output-1
**
*Output, history, variable=PRESELECT
*End Step

 

My Company - Red Cedar Technology

Subscribe to Comments for "ABAQUS CAE can not find the time step"