You are here
A warning message in Abaqus/ Explicit data file!
Dear colleagues
During the analysis of my projects, I always monitor the procedure. I encountered a strange warning which was not shown in error or warning tab in the monitiring part, but when I check the data file I saw it! you can see the warning in following:
"
***NOTE: 84 SLAVE NODES INVOLVED IN *TIE CONSTRAINT
HAVE BEEN ADJUSTED. FOR MORE DETAILED INFORMATION ON
NODAL COORDINATE ADJUSTMENTS, USE THE *PREPRINT,MODEL=YES
OPTION.
***WARNING: THE FOLLOWING SLAVE NODES INVOLVED IN *TIE,
ARE WITHIN COMBINED MASTER AND SLAVE THICKNESS AWAY FROM
THEIR PROJECTION POINTS ON THE MASTER SURFACE. THE
COORDINATES OF THESE NODES HAVE THEREFORE NOT BEEN
ADJUSTED.
25896 25885 24642 24631 23388 23377 22134 22123 20880
20869 19626 19615 18372 18361 17118 17107 15864 15853
14610 14599 13356 13345 12102 12091 10848 10837 9594
9583 8340 8329 7086 7075 5832 5821 4578 4567
3324 3313 2070 2059 816 805 "
Is it any critical warning? Do you have any idea what the problem in interaction module is?
Regards
Recent comments