I want to understand how the stress update algorithm is modified for the different definitions of stress rate in ABAQUS/Standard and ABAQUS/Explicit formulations. I know the relationships, I just want to see how it's coded in a subroutine.
Also, the Hughes-Winget algorithm is used to update the stress defined by the Green-Naghdi stress rate by using the Jaumann rate. How to implement that in VUMAT? Can someone please post an example to clarify these aspects?
Abaqus mailing list
Hello
subscribe to and seek assistance from the
ABAQUS mailing list
https://groups.yahoo.com/neo/groups/Abaqus/info
Search the archive of the list before posting in it.
Good luck