FEA of Prosthetic Lens Insertion During Cataract Surgery

Submitted by SIMULIA on

Cataract surgery is the most common surgery in America today. Modern surgeries require the opacified crystalline lens to be removed and for a prosthetic lens to be inserted through a suture-less incision during a 5-10 minute outpatient procedure. The industry is driving for smaller incisions by redesigning the lens and insertion device geometry in addition to new materials. Typical lens dimensions are 6mm diameter with a center thickness of 1mm which is inserted through a 2.8mm incision. For the insertion the lens is folded and elongates while advancing down a tapering tube.

FEA of a proximal humerus fracture with a fixation plate

Submitted by SIMULIA on

The fracture of the proximal humerus is the second most common injury to the upper extremity. In severe fractures, surgery may be necessary which can be in the form of a locking plate holding the bones in place. This study examines the effect of including a bonegraft alongside the locking plate. ScanIP and +ScanCAD (Simpleware Ltd) were used to segment the proximal humerus from a CT scan, and to introduce CAD data of the fixation plate and bonegraft.

Fatigue Life Estimation of Nitinol Medical Devices

Submitted by SIMULIA on

Stents have been used in the treatment of coronary artery disease for decades, and their use in the peripheral arterial vasculature is growing rapidly. Mechanical loads imposed on peripheral stents may include loads due to arterial pulsation, axial compression, bending and torsion. These stents are most often manufactured using nitinol, a nickel-titanium alloy that exhibits unique shape memory and superelastic characteristics. Finite element analysis can be a powerful tool in designing medical devices to withstand such a rigorous loading environment.

Ceramic Total Hip Liner Fracture Modeling in Abaqus using co-Simulation and Extended Finite Element Modeling

Submitted by SIMULIA on

Due to concerns over particle generation in conventional metal-on-polyethylene hip bearings used in total hip arthroplasty (THA), interest in advanced low-wear bearing alternatives such as ceramic-on-ceramic (CoC) couples has reemerged. While ceramics demonstrate excellent

Bone Remodeling Response During Mastication on Free-End Removable Prosthesis – a 3D Finite Element Analysis

Submitted by SIMULIA on

An understanding of functional responses in oral bone is a crucial component of dental biomechanics. The purpose of this study was to investigate the use of an osseointegrated implant as support for a free-end removable partial denture (RPD) on the potential biological remodelling response during mastication. A three-dimensional (3D) finite element analysis (FEA) was performed to determine the biomechanical responses to masticatory loading in the posterior mandible.

Biomechanical study of a drop foot brace

Submitted by SIMULIA on

A person specific drop foot brace was simulated in the commercial finite element code Abaqus.The geometry was imported from a 3D optical scan of the actual surface and modeled as a composite material layup defined in a local discrete material coordinate system. The finite

element model was used in order to model the stance phase in a normal walking. The material

choice is a challenging task giving flexibility to the brace together with sufficiently stiffness and

fatigue strength. The simulation has been compared with measurements from a strain gauge

mounted foot brace tested in use. Based on simulations, a large number of expensive trial and

Advanced Material Modeling in a Virtual Biomechanical Knee

Submitted by SIMULIA on

For clinicians and medical device manufacturers, in-vitro and in-vivo testing of the knee are important methods for evaluating treatment techniques. However, numerical models that can provide much of the same information will become of more service and are a new focus of the modeling community. A continued effort has centered on specimen-specific anatomical and functional models, in terms of both geometry and mechanical properties of the tissue constituents.

Achieving a more Accurate Prediction of a Polymer Snap Deformation Pattern

Submitted by SIMULIA on

A variety of polymers are used extensively for both medical applications and consumer products. Most of these polymers exhibit time-dependant behavior which varies significantly with environmental conditions. Injection molding technologies generally offer application design freedom and options for several functions build into each component. Meanwhile analysts are often faced with the difficulties of predicting the response of the final product.

3D Numerical Analysis of an ACL Reconstructed Knee

Submitted by SIMULIA on

Numerical methods applicable to the tibia bone and soft tissue biomechanics of an ACL reconstructed knee are presented in this paper. The aim is to achieve a better understanding  of the mechanics of an ACL reconstructed knee. The paper describes the methodology applied in the development of an anatomically detailed three-dimensional ACL reconstructed knee model for finite element analysis from medical image data obtained from a CT scan. Density segmentation techniques are used to geometrically define the knee bone structure and the encapsulated soft tissues configuration.