Skip to main content

combining Abaqus/Standard and Abaqus/Explicit?

Submitted by Ahmad Falahatpisheh on

How can I run an analysis that starts in Abaqus/Standard and can be continued in Abaqus/Explicit? Does Abaqus automatically take care of data exchange between them or it should be manual. In other words, can I define step1 in a model run by Abaqus/Standard then immediately running step2 under Abaqus/Explicit?



Thanks,

Ahmad Falahatpisheh

PhD student of Mechanical and Aerospace Engineering

Edwards Lifesciences Center for Advanced Cardiovascular Technology

2141 Engineering Hall

University of California, Irvine



 

Hello,

 I have done it, it is possible, but you should be careful. Some things cannot be imported from Standard to Explicit and vice versa. Some things (e.g. BC, contacts) should be new defined. The Users Manual gives you al the details you need. It is often used for metal forming (explicit) with springback (implicit).

Best regards,

Andras