Hello colleagues.
I am solving a ring as an axisymmetric solid. I apply displacements and define reactions. According to an experimental data calculated reactions twice larger. We think it because the ring is thin and it is too rigid in solid formulation. Did anyone see solid formulation with a rotational DOF, i mean in any other FEA products?