Skip to main content

Blog posts

Simulation of Lumbar Spine Biomechanics Using Abaqus

Submitted by SIMULIA on

Biomechanics testing of the lumbar spine, using cadaveric specimens, has the advantage of using actual tissue, but has several disadvantages including variability between specimens and difficultly acquiring measures such as disc pressure, bone strain, and facet joint contact pressure. A simulation model addresses all of these disadvantages. The objective of this work is to develop a method to simulate the biomechanics of the lumbar spine. A process is currently being used to convert a CT scan of a lumbar spine into a simulation model.

Periprosthetic stress shielding in patello-femoral arthroplasty: a numerical analysis

Submitted by SIMULIA on

Total knee replacement gives proven good results for isolated patello-femoral osteoarthritis, but patello-femoral arthroplasty may be more appropriate because only the joint compartment is replaced. Although the femoral component of a patello-femoral prosthesis is smaller than in total knee arthroplasty, it is unknown whether strain-adaptive periprosthetic bone remodeling occurs following patello-femoral arthroplasty. The aim of the study was to evaluate and compare the stress shielding effect of prosthetic replacement with Finite Element (FE) modeling.

Optimization Module for Abaqus/CAE based on Genetic Algorithm

Submitted by SIMULIA on

Genetic algorithms have become one of successful tools in design and topology optimization. The optimization module based on genetic algorithms was developed and employed in Abaqus/CAE by GUI and kernel scripting. The new module extends advanced functionality of Abaqus/CAE allowing to perform optimization directly in Abaqus Unified FEA product suite from SIMULIA. The genetic algorithms implemented in optimization approach are based on available GPL libraries.

Numerical Study of Metal Fatigue in a Superelastic Anchoring Stent Embedded in a Hyperelastic Tube

Submitted by SIMULIA on

In this study we compare various way of quantifying high cycle radial fatigue behavior in a percutaneous Mitral repair device using Goodman methods. In order to provide an improved representation of the tissue-device interaction, we use an Ogden hyperelastic model to  simulate the native vessel with parameters obtained from pressure-diameter test data of human cadaver heart coronary tissue, and published data presented in previous work.

Modeling Respiratory Motion for Cancer Radiation Therapy Based on Patient-specific 4DCT Data

Submitted by SIMULIA on

Prediction of respiratory motion has the potential to substantially improve cancer radiation therapy. A nonlinear finite element (FE) model of respiratory motion during full breathing cycle has been developed based on patient specific pressure-volume relationship and 4D Computed Tomography (CT) data. For geometric modeling of lungs and ribcage we have constructed

Material Modeling of Polylactide

Submitted by SIMULIA on

Computational modeling of stents can provide insight into critical locations (high stress/strain regions), help with design iterations/optimization, and reduce the need for bench-top testing. This study focuses on the developmental efforts to create a material model that can capture the mechanical response of poly-L-lactide (PLLA), the backbone of Abbott Vascular’s ABSORB Bioresorbable Vascular Scaffold (BVS). PLLA is an anisotropic, viscoplastic material.

Investigation of Interaction between Guidewire and Native Vessel Using Finite Element Analysis

Submitted by SIMULIA on

Endovascular aneurysm repair involves insertion of an introductory component called guidewire through native vessels to help with the guidance of the delivery catheter. Guidewire tends to alter the vessel geometry due to its higher stiffness compared to the vessel wall. Very limited data is available to understand such interactions. Investigation of interaction between guidewire and native vessels could provide useful insight into vessel stresses and guidewire deformation in-vivo.

Interaction between Short Surface Cracks and Residual Stress Field in Shot Peened Titanium Samples

Submitted by SIMULIA on

To enhance the fatigue life of metal components, frequently compressive stress is introduced to the surface layer. Although procedures such as shot peening have been practiced for many decades in other industries, an improved understanding of the fundamental mechanics that leads to the improved performance is desired. From a continuum mechanical point of view, the interaction between the crack and the stress intensity field is the factor determining whether the crack will propagate.

Fracture analysis of the battery cans for Implantable Pulse Generators

Submitted by SIMULIA on

The stresses in a battery housing used in Implantable Pulse Generators (IPGs), also known as pacemakers, were investigated using Abaqus/Standard. There were three levels of analysis: the global level, the three-dimensional submodel level and the plane strain submodel level. The output of the global analysis was fed into the three-dimensional submodel analysis and subsequently the output of the three-dimensional submodel analysis was fed into the plane strain submodel analysis.

FEA of Prosthetic Lens Insertion During Cataract Surgery

Submitted by SIMULIA on

Cataract surgery is the most common surgery in America today. Modern surgeries require the opacified crystalline lens to be removed and for a prosthetic lens to be inserted through a suture-less incision during a 5-10 minute outpatient procedure. The industry is driving for smaller incisions by redesigning the lens and insertion device geometry in addition to new materials. Typical lens dimensions are 6mm diameter with a center thickness of 1mm which is inserted through a 2.8mm incision. For the insertion the lens is folded and elongates while advancing down a tapering tube.